Table Allowable surface stress (MPa) for a 3seconds duration load according to ASTM E [22]. The 3seconds duration load that represents the. New Provisions in ASTM e‐ A comparison of the Basic and New Analytical Procedures for Determining the. Load Resistance of. for glass strength, ASTM E , “Standard Practice for Determining the Minimum Thickness and Type of Glass. Required to Resist a Specified Load” which.
Author: | Melrajas Shaktigul |
Country: | Hungary |
Language: | English (Spanish) |
Genre: | Marketing |
Published (Last): | 2 September 2013 |
Pages: | 203 |
PDF File Size: | 13.5 Mb |
ePub File Size: | 2.63 Mb |
ISBN: | 294-9-87017-884-7 |
Downloads: | 89764 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Tosida |
Link to Active This link will always route to the current Active version of the standard.
It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations asgm to use.
For conversion of quantities in various systems of measurements to SI units refer to SI Active view current version of standard.
Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. For more information about, or to purchase a copy of, the complete program, call Standards Design Group toll-free at or visit their web site at: This calculator makes it easy for you to perform preliminary assessments of the Wind Load resistance of single glazed, annealed not heat treated window glass, with various edge support conditions, according to the ASTM E standard.
Wind Load Calculator
Please note that we are providing this calculator as a tool for you to use with no expressed or implied warranties regarding the results, and while we have made every effort to assure the accuracy of the calculations, Pilkington will not be responsible for the results or any subsequent problems xstm may occur as the result of the use of the information contained herein.
Glass must be selected and designed to conform with applicable Safety and Building Code Requirements.
About this site Legal Notice Privacy Policy. Maximum glass deflection and edge pullout under the design load should always be considered.
Skip navigation Skip to section menu Skip to page menu. Appendix X3 presents a procedure e1300-04 compute approximate probability of breakage for annealed monolithic glass lites simply supported on four sides. Click Here to Begin D Practice for Plastics: Head Office – Mita Minato-ku Tokyo.
ASTM E1300 Wind Load Calculator
Work Item s – proposed revisions of this standard. This practice shall not apply to other applications including, but not limited to, balustrades, glass floor panels, aquariums, structural glass members and glass shelves. Determination and Report e13300-04 Procedures.
Appendix X1 and Appendix X2 provide additional procedures to determine maximum lateral deflection for glass simply supported on four sides. This practice assumes that 1 the supported glass edges for two, three and four sided support conditions are simply supported and free to slip in plane 2 glass supported on two sides acts as a simply supported beam, and 3 glass supported on one side acts as a cantilever.
The values given in parentheses are for information only.
ASTM E – 04 Standard Practice for Determining Load Resistance of Glass in Buildings
If the application does not appear within 1e300-04 few seconds generally less than 30 seconds under normal conditionsyou may need to download the plug-in by clicking here. Nippon Sheet Glass Co. The final thickness and type of glass selected also depends upon a variety of other factors see 5. Not all glass types are manufactured by Pilkington North America, Inc.